Product Description
Fire & Acoustic T-Block Barrier System for Masonry AND Framed Constructions.
The Stoneshield Fire Safe T Block is manufactured from A1 non-combustible Rockwool insulation and encapsulated in a protective sleeve. This robust fire barrier is designed to prevent fire penetration, reduce sound transmission, and maintain thermal integrity in external wall cavities at junction points.
Product Options & Installation
The Stoneshield Fire Safe T Block is designed to be compression fitted into the wall junction during construction, requiring no additional fixings. It is essential to ensure the correct size barrier has been selected for the cavity width, with a minimum of 10mm compression achieved upon completion. Any cavity insulation should be cut back to maintain correct compression between the inner and outer leaf. Joints must be tightly butted to maintain a continuous fire seal. A optional DPC can be added to any size requested.
Technical Data
Independently tested to BS EN 1366-4:2021, the Stoneshield Fire Safe T Block offers a fire rating of up to 120 minutes. Suitable for use with various boards on timber and steel framing systems. Timber-based boards must have a minimum density of 500kg/m³, while other carrier boards must have a minimum classification of A2 – s1 d0. Minimum permissible board thickness is 9mm. Manufactured from Fiberstone A1 non combustable stone wool slab
Storage
Store the Stoneshield Fire Safe T Block in a dry location out of direct sunlight.
Disclaimer
The information provided in this datasheet is for general guidance purposes only and does not constitute professional advice. It is the responsibility of the user to ensure proper installation, maintenance, and compliance with relevant guidelines.